Syntax
SET CASSPOOL_LOCK_RETRY_COUNT=count
Values
count The number of retries made to obtain a record lock.
Default
If not specified, this variable defaults to 20.
Allows the specification, in tenths of seconds, of the maximum time out period that will be used with any LSC style application, such as Drag and Drop, SourceConnect, or the Monitor. The maximum value that can be used is 2,147,483,647.
Syntax
SET CCITIMEOUT=value
Default
The default is 1200 (2 minutes).
ExampleSET CCITIMEOUT=2400
Syntax
set CCITCP2=hostname
Parameters
hostname is the TCP hostname or dotted decimal IP address of the machine running the CCITCP2 daemon you wish to contact from that session.
Comments
The environment variable value will always take precedence over any value set using the Configuration Utility. To restore a process to using the value set by the Configuration Utility simply set the environment variable to an empty string, such as
set CCITCP2=
Alternatively, if this environment variable is set system-wide (by creating a system variable in the system environment settings, or by using a CONFIG.SYS file) then this value will always take precedence over any value set using the Configuration Utility.
Syntax
set CCITCP2_PORT=port
Syntax
set CCITCPS_server_name=port
Parameters
Note that this will only work if the server application process is started in the same session or process that has this environment variable set.
Example
set CCITCPS_server_name=MFPORT:3000
If a client is known to be trying to connect to a server with Server Name server_name, and the TCP address and port (e.g. 3000) that the server is using is known, then the client can be made to connect directly to it by setting this environment variable.
Syntax
CCITCPT_server_name=MFNODE:server_hostname,MFPORT:port_number
Note that this can be used instead of setting the client Machine Name value. This is useful if the Machine Name value the client specifies cannot be altered by an application defined method.
Parameters
Example
CCITCPT_server1=MFNODE:server2,MFPORT:3000
Syntax
CCITRACE=filename [options]
/F or -F | logs the details of CCI API calls to the trace file. The default is OFF, unless a filename any other trace option is specified, in which case it is always ON. |
/P or -P | logs the details of protocol-level calls to the trace file. The default is OFF. If this flag is OFF, then only the details of the CCI user-level API will be traced. If this flag is ON, the level of function tracing may be greatly increased. |
/D or -D | logs the contents of all buffers passed to and from the CCI functions. The default is OFF. Data tracing may not be allowed if the application has been coded to prohibit data tracing for security reasons. |
So to create a CCI trace file with the default name of ccitrc1.trc (with matching ccitrc1.idx file) which traces CCI API function flow, along with the underlying protocol function flow, but with no tracing of the user data passed to these calls, the value of the CCITRACE environment variable would be /P.
The CCI.INI file can also be used to control trace options, but any values specified by the CCITRACE environment variable will take precedence.
Specifies a run-time configuration file that tailors the run-time configurable options in some way.
Syntax
SET COBCONFIG=pathname
Parameters
Comments
If $COBCONFIG is not set then the file $COBDIR/etc/cobconfig is searched for instead.
Example
SET COBCONFIG=/home/mydir/cobconfig
Values
Specifies the directory or directories that the Compiler and Animator should search for copyfiles.
Syntax
SET COBCPY=pathname[:pathname]...
Parameters
A directory that the Compiler and Animator are to search when looking for copyfiles. When more than one pathname is present, a null pathname represents the current working directory.
Example
SET COBCPY=/home/group/sharedcopy::mydir/mycpy
causes the Compiler to search for a copyfile in /home/group/sharedcopy, then in the current directory and finally in ./mydir/mycpy until either the copyfile is found or it can be considered not found.
Specifies the directory or directories that the run-time system is to search for data files. Provides you with the facility to map data files globally, thus enabling you to put working data files in a directory whose name is not known until run time.
Syntax
COBDATA=pathname[:pathname]...
Comments
COBDATA affects the compiler and other utilities. During compilation, for example, program source is regarded as a data file by the compiler. If you intend to use any COBOL development system utilities, we recommend that the COBDATA value starts with a colon (:).
COBDATA is considered set if there is an environment variable of this name in your environment space, and its value is non-empty.
The full mapping order for files is:
For multiple directory paths specified either in the COBDATA environment variable or a dd_ environment variable, the system searches the first directory specified followed by a slash (/) as a prefix to the user name.
If the filename is not found, or is not readable, the search continues with the next directory until the final directory has been searched. If no file is found, the first directory is used if a file is to be created.
Any dd_ and COBDATA mappings are ignored for any filename that starts with a hyphen () or a slash (/). In addition, it is illegal to have a hyphen in an environment variable name.
When using this facility, you should not use a filename that starts with "COB... "(these are reserved for the COBOL system).
You can use the COBDATA environment variable for files open in any mode (including OUTPUT) and for fixed or variable length files. If you are using indexed files, both the data and index files must be in the same directory.
The COBDATA environment variable affects file deletes, using the rules given here, as well as file opens.
If you intend to use COBOL development system programs, we recommend that you first unset COBDATA, as many of these programs open data files and are thus affected by the value of COBDATA. If you have to set COBDATA, you should include the paths :$COBDIR/dynload/helptbox.lbr and :$COBDIR/dynload/check.lbr at the beginning of the COBDATA value. If you want to see the Animator Help pages, also include COBDIR/dynload/advanim.lbr.
Example
SET COBDATA=:demo:/home/data:progs
causes COBDATA to be set to instruct the runtime system to search for data files in the current directory, then in the directory ./demo, then in the directory /home/data and finally in ./progs.
Specifies the directory where the required Micro Focus COBOL system is installed. Many of the COBOL system components and utilities require and use this information. If the COBDIR environment variable is not set then the COBOL system acts as if it had been set to the default COBOL system directory.
SET COBDIR=pathname
Parameters
Comments
The Micro Focus COBOL system is normally installed in the default COBOL system directory and so does not require COBDIR to be set. COBDIR only needs to be set when your COBOL system has been installed in a different directory such as when more than one version of the COBOL system is available at the same time.
Example
SET COBDIR=/home/products/cobse20
This causes the Cob utility to search the directory /home/products/cobse20 for the Micro Focus COBOL system software.
Specifies which Java Virtual Machine (JVM) to load.
SET COBJVM=platform_nnn
Parameters
platform_nnn where
Comments
You might need to set COBJVM if you are developing distributed applications with both COBOL and Java components.
Example
SET COBJVM=ibm_122
Specifies the maximum elapsed time, in tenths of a second, for the connected terminal to transmit any valid escape sequence to the runtime system.
When a terminal key is depressed, the terminal might send in response a single character or a group of characters to the runtime system. Typically, such a group of characters starts with an escape character and the group of characters is known as an escape sequence. A terminal might send an escape sequence for one depression of a function key. It might also send the same sequence of characters for a depression of the Escape key followed by the depression of one or more alphabetic or numeric data keys. The only difference apparent to the runtime system is the interval between the arrival of each character; the user cannot type as fast as the escape sequence is generated by the terminal.
If a terminal is connected over a network that sends the characters to the runtime system in discrete packets, then the network can alter the intervals between each character arriving at the runtime system. COBKEYTIMEOUT is available to help compensate for typical network delays so the runtime system identifies escape sequences correctly.
Syntax
SET COBKEYTIMEOUT=n
Parameters
n A number in the range 1 through 126 that represents the maximum elapsed time required for a terminal to transmit any valid escape sequence to the runtime system over the line or network connection. On encountering a lone Escape character, the runtime system waits n tenths of a second before assuming that the character does not introduce an escape sequence. The runtime system calculates an appropriate default value for n from the baud rate of the terminal.
Example 1:
COBLPFORM 1:3:5:7:9:11:13:15:17:19:21:23
In this example C01 equals 1, C02 equals 3, and so on.
Example 2:
COBLPFORM :3::5: :9
In this example, C01 equals 3, C02 equals 5, C03 equals 1, and C04 equals 9. You can specify only a single line number for each channel.
In example 2 above, channels C05 - C12 are undefined. If a print statement specifies channel C05 - C12, the line is printed at line 1. In addition, in the example shown, C03 equals 1 because its value is a space and therefore undefined.
Any WRITE BEFORE/AFTER PAGE statements cause positioning to be at line 1. Each line advance increases the line number by one. A request to skip to a line number less than or equal to the current line causes a new page to begin. The appropriate number of line feeds are then generated.
Specifies the size of the main stack.
Syntax
SET COBMAINSTACK=n
Parameters
n A number in the range 1 through nnn that represents the size of the main stack.
Comments
You might need to set COBMAINSTACK in any of the following circumstances:
If you are using the multi-threaded run-time system
If you have IF STATEMENTS with a very large number of ELSE clauses
Specifies the directory or directories that the runtime system is to search for dynamically loadable .int and .gnt files, or callable shared objects.
Syntax
SET COBPATH=pathname[:pathname]...
Parameters
pathname A list of search directories, each item separated by a semicolon, that the runtime system is to search for a dynamically loadable program (.int, .gnt or callable shared object) file. When more than one pathname is specified, a null pathname represents the current working directory.
Example
SET COBPATH=u:/home/mydir/srclib:otherlib
Specifies the name of a print spooler that is to receive, via its standard input stream (stdin), output from any DISPLAY UPON PRINTER statement.
Syntax
SET COBPRINTER=command-line
Parameters
Comments
Each DISPLAY UPON PRINTER statement executed by your COBOL program causes a new invocation of command-line. Each invocation receives the data referenced in the DISPLAY statement, and is followed by a system end-of-file condition.
Example
SET COBPRINTER="myspooler -a $TMPDIR\spoolfile"
Syntax
SET COBSW=[+/-}s...
A list of the runtime switches to set or unset.
Example
SET COBSW=+0+D
This enables runtime switch 0 and the ANSI COBOL debug switch.
Values
Syntax
SET ENTRYNAMEMAP={filename|directory}; ...
Parameters
filename An entry map file.
directory A directory containing an entry name map file. The name of the entry name map file must be mfentmap.dat.
Comments
You must set the entry_name_mapper tunable to enable entry point mapper support.
If ENTRYNAMEMAP is not set, the runtime system searches for an entry name map file called mfentmap.dat in each folder specified by the COBDIR environment variable.
If the runtime system finds more than one entry name map file and same entry point is defined differently in different files, precedence is given to the definition in the entry name map file that was found first. To change the order in which the runtime system finds entry name map files you need to change the order in which the files appear in the COBDIR or ENTRYNAMEMAP environment variable paths.
Syntax
SET ES_ACBLIB={pathname
Values
pathname The path location of the IMS ACB files.
Default
If this variable is not set the ACB files are assumed to be in the project directory.
Syntax
SET ES_ALLOC_EXPAND=value
Values
Y Expands an environment variable used to specify an allocation path.
N Do not expand the variable used in the path.
Default
The default value is Y.
Syntax
SET ES_ALLOC_OVERRIDE=rules-file
Values
rules-file The file path and name of the dataset rules file.
SET ES_CERT_REG=pathname
pathname Pathname of the directory where registrations are stored.
By default no directory is specified. In this case it must be specified on the cascertreg command.
SET CESN_NO_OS390=value
Specific invalid user/password messages will be produced.
Syntax
SET ES_CICS_SINGLE=value
ES_CLASS_XPCT=value
ES_CLASS_XCMD=value
ES_CLASS_XDCT=value
ES_CLASS_XFCT=value
ES_CLASS_XJCT=value
ES_CLASS_XPPT=value
ES_CLASS_XPSB=value
ES_CLASS_XRES=value
ES_CLASS_XTST=value
ES_CLASS_XTRAN=value
ES_CLUSTER=ON
ES_CLUSTER_ISC_TRACE=value
ES_CLUSTER_LISTENER_PORT_TO_USE=port
ES_CONSOLE_LOG=port export ES_CONSOLE_LOG
Can be any combination of the following:
ES_CSKL_NO_MSG_CONSOLE=value
ES_DDBG_PORT_RANGE=value
Example
ES_DDBG_PORT_RANGE=8001-8040
ES_DISABLE_DFLTUSR_SIGNON=value
ES_DFS3650=value
ES_ECI_MAX_RESP=value
ES_ESM_CMDSEC=value
ES_ESM_IDPW_CASE=xy
Values for both x and y are:
Default
Legacy behavior.
Comments
When this environment variable is set, Enterprise Server will only make one attempt to identify a user presenting the user ID and password as is (M), folded to uppercase (U) or folded to lower case (L). If this environment variable is not set, the legacy Enterprise Server behavior will be used.
For the legacy behavior for CICS, the User ID and the password are used as supplied possibly filtered by the uppercase translation configuration of the sign-on transaction.
For ESMAC and IMS, the legacy behavior is that, first, the user ID and password are used as supplied. If the authentication fails, the user ID is folded to uppercase and used again. If this fails as well, both the user ID and the password are folded to uppercase and then used.
Example
ES_ESM_IDPW_CASE=UM - a single authentication is tried with the user ID folded to uppercase, and the password used as-is.
ES_ESM_PLTPISEC=value
Default
NONE
ES_ESM_PLTPIUSR=userid
ES_ESM_RCF=value
ES_ESM_RESSEC=value
ES_ESM_SECPRFX=value
ES_ESM_XUSER=value
ES_ESMAC_DISP_MAX_OVERRIDE=value
ES_EUSA_SIZE=number
ES_GLM=value
This variable only applies to the region within an Enterprise Server Cluster designated as the GLM.
ES_GLM_TIMEOUT=secnds
ES_HOSTNAME_TO_USE=hostname
Values
Example
ES_IMS_BYPASS_OTMA_DEST_RES=Y
ES_IMS_MESGQ=[ds-file-name];max-blocks;buffer-count;start-control;[cushion-size]
Y | Cold start the resource definitions. Default. |
S | Cold start the statistics and resource state information. |
Q | Cold start the data store (system cold start). |
Determines whether the PL/I program converts the PCB address list from a direct to an indirect addressing technique. Set the variable to one of the following:
The default is D (which stands for dynamic).
Syntax
set ES_INQFILE_RETURN=value
Parameters
Default
PCN
Syntax
SET ES_JESYSMSG_OUTPUT==Y|N
Values
Default
The default is N.
ES_JES_LEVEL=type
ES_JES_RESTART=value
ES_JES_SPOOL_ORDER=value
1 - Displays the list in descending order by JOBID. Any other value displays it in ascending order.
ES_LE370_SUPPORT=value
ES_LEGACY_ECI=value
ES_MAX_CATALOG_LINES=number
ES_MFASM_SUPPORT=value
Assembler supported for CICS server regions.
No Assembler supported for CICS server regions.
ES_MFSLIB=pathname
ES_MOD3650=filename
Syntax
SET ES_MQ_1PC=value
Values
Default
By default ESMQXA does not operate in one-phase commit mode.
Syntax
SET ES_MQ_LISTENER={QueueManagerName,QueueName,ListenerName} [,QueueManagerName,QueueName,ListenerName}...Values
QueueManagerName,QueueName,ListenerName - the characteristics of the listener being defined.
Default
By default, no WebSphere MQ listeners are defined.
Syntax
SET ES_MQ_XA=valueValues
Default
By default, a dynamic XA structure is used.
SET ES_OLD_SEC_TSTD=value
SET ES_OTMA_TIMEOUT=seconds
Syntax
ES_PL1_MFFH=Y|N
Values
Y Micro Focus File Handler is used to perform all Open PL/I I/O operations.
N All I/O is routed to old Liant file handlers.
Default
The default value is Y.
Syntax
ES_PL1_MFFH_JCL=Y|N
Values
Y You can run Open PL/I programs that access JCL data definitions.
N Open PL/I programs cannot access JCL data definitions.
Default
The default value is N.
Syntax
ES_PLI_SUPPORT=value
Values
Default
PL/I support is not enabled.
Syntax
SET ES_RLS_FILE_SUPPORT=value
Values
Default
RLS file support is off.
Syntax
ES_SEP_DORMANT_TIME=seconds
Values
Default
Transient SEPs are terminated after 2 seconds of inactivity.
Syntax
ES_SERVER=name
Values
Default
ESDEMO/ESDEMO64
Syntax
ES_SURROGATE_JOB_USER=value
Any value - The user ID that started the ES region is used in the job submission.
Default
By default, the CICS default user CICSUSER, or as specified by ES_USR_DFLT_CICS, is used in the job submission.
Syntax
SET ES_TMC_AGGREGATE={[,N|,D]|nnn,Y}
Values
See Server Instance Properties: MSS IMS TM General for details.
Once a thread reaches a key transactional point and requests a flush, TM waits the specified interval to accumulate subsequent threads that also request a flush. At the end of the interval, one flush is performed for all accumulated requests thus potentially improving performance by reducing the number of flush commands issued to the operating system.
Default
,N
Syntax
SET ES_TN2370_FORCE_ALT=value
Values
Default
The default screen size is used.
Syntax
SET ES_TN2370_MODEL_LOG=value
Values
Default
Model names are not logged.
Syntax
ES_TEST_TRANCLASS={Y|N}
Values
Y | Activate transaction class support |
N | Do not activate transaction class support |
Default
N, no transaction class support.
Syntax
ES_TRANCLASS_CWI={TCPIPSERVICE|URIMAP}
Values
TCPIPSERVICE | Prioritize and limit TCPIPSERVICE transactions |
URIMAP | Prioritize and limit URIMAP transactions |
Default
TCPIPSERVICE
Syntax
SET ES_TRX3650=transaction
Values
Syntax
SET ES_USR_DFLT_CICS=user
Values
Default
CICSUSER
Syntax
SET ES_USR_DFLT_ESMAC=user
Values
Default
mfuser
Syntax
ES_ESM_DISABLE_DFLTUSER_ESMAC=value
Values
Default
Default ESMAC user is not disabled.
Syntax
SET ES_USR_DFLT_JES=user
Values
Default
JESUSER
Syntax
SET ES_USR_DFLT_IMS=user
Values
Default
IMSUSER
Syntax
ES_XA_????_NB_RETRIES=nnnn
Values
Default
5 retries (ES_XA_RECONNECT must have been set).
Syntax
ES_XA_LOG_SUPPRESS=value
Values
Default
By default no value is specified and XA logging is not suppressed.
If this environment variable is set, when an error occurs on a call to XA, the server recycles the SEP and attempts to reconnect to the Resource Manager. The ES_XA_????_NB_RETRIES variable specifies the number of XA call failures allowed before the SEP is recycled and the switch disabled.
Syntax
SET ES_XA_RECONNECT=user
Values
Default
No value is set and the XA reconnect feature is not enabled.
Syntax
SET ES_EZASOKET_SUPPORT=value
Values
Default
By default no value is set and EZASOKET support is not enabled.
Syntax
SET EXTFH=filename.cfg
Parameters
filename.cgf The name of the configuration file.
Example
SET EXTFH=/home/mydir/myconfig.cfg
Syntax
SET FHREDIR=filename.cfg
Parameters
filename.cfg The name of the configuration file.
Example
SET FHREDIR=/home/mydir/myconfig.cfg
Specifies a configuration file to be used by the Fileshare Server.
Syntax
SET FS=filename.cfg
Parameters
filename.cfg The name of the configuration file.
Example
SET FS=myconfig.cfg
Syntax
SET FSCOMMS="\$local"
Parameters
"\$local" Run the Fileshare System in single user mode.
Syntax
SET HCOBND=pathname
HCOBND=pathname export HCOBND
Parameters
pathname The directory that the DB2 ECM is to use to store bind files.
Example
SET HCOBND=d:\mydir\binds
Comments
The DB2 ECM uses the specified directory until the variable is unset or reset to a different directory. The DB2 Compiler directive option BIND overrides this environment variable.
Syntax
SET MAINFRAME_FLOATING_POINT=fpstatus
Parameters
fpstatus Which format to use for floating point data items. This must be one of:
Setting MAINFRAME_FLOATING_POINT to anything other than true has the same effect as setting it to false.
The setting of this environment variable can be overridden by the NATIVE-FLOATING-POINT directive.
MF_MVSJOB=<lower value>{-|+}<upper value>Where:
set MF_MVSJOB=0000010+0000100This resets the values to start with job number 10 and run through to job number 100. When the upper limit has been reached you receive a message:
All job numbers in the range 0000010:0000100 are in useAt this point you need to remove some jobs from the spool - you can use the spool housekeeping functions to do this.
This environment variable can be used to enable a 7-digit Job number limit. If the <upper value> mentioned is greater than 99999, then 6+ digit job number support is enabled. The maximum value that can be set is 9999999.
If a value set using this variable is not valid, the default values of <0001000>{-|+}<0099999> are set.
Syntax
SET MF_SPOOL_ARCHIVE_LOC=file-location
Values
file-location The file location.
Determines if the MFELX* files associated with a job are also deleted when spool housekeeping is run.
Syntax
SET MF_SPOOL_HK_LEX_SCAN=Y|N
Values
Y The files are deleted.
N The files are not deleted.
Default
The default is Y.
Syntax
SET MF_SPOOL_HK_OUTPRTC=value
Values
Y Files from the Complete queue are deleted.
NFiles from the Complete queue are not deleted.
Default
The default is Y.
Syntax
MF_SPOOL_HK_TESTDATE=YYYYMMDD
Values
YYYYMMDD The date which is to override the normal date.
Default
If this variable is not set, the normal date for the spool housekeeping is used.
Syntax
SET MF_SPOOL_HK_WRITE_PROFILES=Y|N
Values
Y Profile files are created.
N Profile files are not created.
Default
The default is Y.
Country Code (MFCODESET) |
EBCDIC CCSIDs | Language |
---|---|---|
AUTOMATIC
AUTO |
Operating system default - sets country code based on CBL_GET_OS_INFO | |
DEFAULT | For a single-byte character set environment, 0437 (US English) selected; else 0081 (Japanese Katakana Extended) selected. | |
0031 | 37, 1140 | Dutch |
0033 | 297, 1147 | French |
0034 | 284, 1145 | Spanish |
0039 | 280, 1144 | Italian |
0043 | 273, 1141 | German (Austrian) |
0044 | 285, 1146 | UK English |
0045 | 277, 1142 | Danish |
0046 | 278, 1143 | Swedish |
0047 | 277, 1142 | Norwegian |
0049 | 273, 1141 | German |
0066 | 838 | Thai Extended |
0081† | 930 (290, 300) | * Japanese Katakana Extended |
0082 | 933 (833, 834) | *Korean |
0086 | 13676 (836, 837) | *Simplified Chinese |
0351 | 37, 1140 | Portuguese |
0358 | 278, 1143 | Finnish |
0437 | 37, 1140 | US English |
0500 | 500, 1148 | International (Latin 1) |
0886 | 937 (37, 835) | *Traditional Chinese |
0930 † | 930 (290, 300) | *Japanese Katakana Extended |
0939 † | 939 (1027, 300) | *Japanese Latin Extended |
9122 † | 9122 (290, 300) | *Japanese Katakana |
Character sets marked with an asterisk (*) are capable of mixed single-byte and double-byte character conversion. EBCDIC CCSIDs in these rows indicate the mixed-byte CCSID first, followed by the single-byte, then double-byte Code Page Global Identifiers (CPGIDs) in parenthesis.
Other EBCDIC CCSIDs in parentheses reflect a 'non-Euro, Euro' pair for appropriate country codes.
For database applications using a DBMS server on Windows, use the table above.
For Windows and UNIX database applications accessing a UNIX database created with single-byte character sets 819 or 923, use the following table:
Country Code
(MFCODESET) |
EBCDIC CCSIDs | Languages |
---|---|---|
1140 | 37,1140 | Dutch US English Portuguese |
1141 | 273,1141 | German (Austrian) German |
1142 | 277,1142 | Danish Norwegian |
1143 | 278,1143 | Swedish Finnish |
1144 | 280,1144 | Italian |
1145 | 284,1145 | Spanish |
1146 | 285,1146 | UK English |
1147 | 297,1147 | French |
1148 | 500,1148 | International (Latin 1) |
A code between 2000 and 9999 (except 9122) corresponds to a user-defined translation table. User-defined tables are created using the Codecomp utility.
If you are not using UK or US language settings, you must also set the codepage in your PC environment settings:
Syntax
SET MFCSCFG=filename
Parameters
filename The name of the configuration file.
Example
SET MFCSCFG=/home/mydir/mfclisrv.cfg
Comments
The value of MFCSCFG is overridden by any value defined in the command line. If neither of the above yields a filename, the default filename mfclisrv.cfg is assumed, and is searched for in the current directory. If that in turn is not found, the default settings for the configuration entries are used.
Syntax
SET MFJSABCODE=code
Parameters
code A decimal value between 1 and 99 representing the abend code to be issued.
Any specified value outside of the range 1 to 99 will result in an abend code of S00D being issued.
Default
By default, this environment variable is not set. If so, and if MFJSERET=ABEND is in effect, an abend S00D (decimal code 16) is issued when a Sort or Merge operation fails with an unrecoverable error.
Example
MFJSABCODE=77
This example results in abend code S04D being issued.
Syntax
SET MFJSERET=ABEND
Parameters
ABEND The operation will abend and its program will continue instead of terminating with an unrecoverable error (return code 16)
Default
By default, this environment variable is not set.
Syntax
SET MFJSSTRICTSORT=ON|OFF
Default
The default is OFF.
Example
MFJSSTRICTSORT=ON
For a COBOL sort not running under mainframe emulation, setting the environment variable MFJSTATS to ON creates a report containing statistics for the SORT that is displayed to SYSOUT. If a report file already exists for a previous SORT, the new statistics are appended to the end of the previous one.
If you are performing a COBOL sort using mainframe emulation, you can create a statistics report by modifying the JCL statement.
Syntax
SET MFJSTATS=switch
Parameters
switch Switches report creation ON or OFF. The default is OFF.
Use this environment variable for Y2K compatibility, when two-digit year values are used.
Syntax
SET MFJSWINDOW=value
Values
To set a sliding century window, set a value between 0 and 100. For example, a value of 80 would set a century window of 1931-2030 in 2011, 1932-2031 in 2012, and so on.
To set a fixed century window, set a value between 1000 and 3000. For example, a value of 1973 would set a century window of 1973-2072.
Default
The default is a sliding value of 80 when emulating DFSORT, and a default value of 0 when emulating SYNCSORT. A value of 0 equates to a century window, starting in the current year.
Comment
You can use this environment variable instead of the Y2PAST sort option.
Example
MFJSWINDOW=25
Specifies a configuration file for Language Environment (LE) runtime options.
Syntax
SET MFLECONFIG=filename
Parameters
filename The file containing the LE runtime options you want to use.
Syntax
SET MFLOGDIR=dirname
Parameters
dirname The name of the directory for log files.
Example
SET MFLOGDIR=/home/mydir/logs
Specifies the record length for the REXX EXECIO command when reading or writing a line sequential file that has been cataloged with a record length of zero.
Syntax
SET SORTCOMPRESS=5
Parameters
5 This is the only value that you can supply. It allows for run-length encoding of sort records, resulting in much better performance when records contain multiple repeated characters.
Comments
This variable is recommended if the sort records contain many single repeated characters, for example, multiple spaces, as it can be very effective in improving memory usage and therefore sort performance.
Example
SET SORTCOMPRESS=5
Syntax
SET SORTSCHEME=1
Syntax
SET SORTSPACE=n[K|k|M|m|G|g]
Parameters
n[K|k|M|m|G|g The amount of memory to be allocated to internal workspace for SORT operations. K or k indicates kilobytes, M or m indicates megabytes and G or g indicates gigabytes. No letter indicates bytes. Defaults to 1 megabyte.
Comments
A larger value for SORTSPACE will generally result in a faster sort. However, if you specify a value that exceeds the capacity of main memory in your computer, such that the operating system has to page memory in and out, performance will be degraded.
Example
SET SORTSPACE=1024K
Syntax
SET SORTTEMPSPACE=n[K|k|M|m|G|g]
Parameters
n[K|k|M|m|G|g] The amount of memory to be allocated to temporary workspace for SORT operations. K or k indicates kilobytes, M or m indicates megabytes and G or g indicates gigabytes. No letter indicates bytes. 32 megabytes is the lowest amount of memory that can be allocated.
Comments
The memory allocation strategy used by SORT can be adjusted through use of SORTTEMPSPACE, which generally improves performance in systems suffering from memory fragmentation.
Example
SET SORTTEMPSPACE=250MB
Syntax
SET SORTTYPE=2
Syntax:
SET XFHLOG=DEFAULT
Parameters:
DEFAULT - generates the log file in the current directory.
Comments:
If the XFHLOG variable is not set, the log file is created in C:\ProgramData\Micro Focus\Enterprise Developer\[version-number] for .NET applications only. This variable has no effect for native applications; the log file is created in the current directory regardless.
The effect of this variable can be overridden by the LOGFILENAME configuration option.