CASST5000 - CASST6002
CASST5000I PLTSD List(plt-name) Processing Started
Shutdown PLT processing has started using the
plt-name
list.
CASST5001I PLTSD - No PLT Specified
Shutdown PLT processing was entered, but no list was specified.
CASST5002S PLTSD - PLT List Open Error
The Resource Definition file could not be opened to read the PLTSD program list table.
CASST5003S PLTSD - PLT List Read Error
The specified PLTSD program list table could not be found in the Resource Definition file.
CASST5004S PLTSD - PLT List not in PPT
The specified PLTSD program list table was not present in the installed PPT.
CASST5005S PLTSD List(plt-name) Program=program abend
A transaction program abend occurred in the
program
program of the
plt-name
list during Phase 2 PLTSD processing.
CASST5006S PLTSD List(plt-name) PLT program program not found
The named program specified could not be found and resulted in a PGMIDERR.
CASST5010I PLTSD List(plt-name) Processing Completed
Shutdown PLT processing has completed successfully using the
plt-name
list.
CASST5020I PLTSD Phase 2 List(plt-name) Processing Started
Shutdown Phase 2 PLT processing has started using the
plt-name
list.
CASST5021I PLTSD Phase 2 - No PLT Specified
Shutdown Phase 2 PLT processing was entered, but no list was specified.
CASST5022S PLTSD Phase 2 - PLT List Open Error
The Resource Definition file could not be opened to read the PLTSD program list table.
CASST5023S PLTSD Phase 2 - PLT List Read Error
The specified PLTSD program list table could not be found in the Resource Definition file.
CASST5024S PLTSD Phase 2 - PLT List not in PPT
The specified PLTSD program list table was not present in the installed PPT.
CASST5025S PLTSD Phase 2 List(plt-name) Program=program abend
A transaction program abend occurred in the
program
program of the
plt-name
list during Phase 2 PLTSD processing.
CASST5026S PLTSD Phase 2 List(plt-name) PLT program program not found
The named program specified could not be found and resulted in a PGMIDERR.
CASST5030I PLTSD Phase 2 List(plt-name) Processing Completed
Shutdown Phase 2 PLT processing has completed successfully using the
plt-name
list.
CASST5201I Spool service shutdown complete
The spool service has terminated normally.
CASST5230I Event Manager Process termination started
The Event Process is terminating.
CASST5231I Event Manager Process termination complete
The Event Manager Process has terminated.
CASST6002I WebSphere MQ gateway (CKTI) shutdown complete
The WebSphere MQ trigger monitor program (CKTI) has disconnected from the queue manager and is terminating.
Parent topic:
CASST Error Messages