When users install the ACUCOBOL-GT Thin Client on a Windows display host, the .atc and .acutc file extensions are automatically associated with the thin client executable (acuthin.exe). As a result, when your browser downloads one of these files, it uses these associations to invoke acuthin.exe. The thin client uses the contents of this file to establish its command-line parameters. The thin client command-line file has a format that resembles other configuration files, and it may contain the following variables:
Variable name | Description |
---|---|
atc-auto-update | Lets you disable the thin client automatic update feature with a setting of "off" (0, false, no) |
atc-user | The logon user name (no default value) |
atc-password | The password given to the server (a required variable when atc-user is used; no default value) |
atc-splash-screen | The option that lets you disable the thin client splash screen with a setting of "off" (0, false, no) |
atc-trace | The trace level (default value is "0") |
atc-server | The name or IP address of the server to connect to (a required variable with no default value) |
atc-port | The TCP port number to use (default value is 5632) |
atc-runtime-options | runtime options passed to the runtime via AcuConnect (no default value) |
atc-alias | The alias to execute (a required variable with no default value) |
atc-cobol-args | COBOL arguments passed to your COBOL program via AcuConnect (no default value) |
Comment lines (preceded by the "#" character) are allowed in this file, as they are in other configuration files.
The contents of the .atc or .acutc file are interpreted by the thin client as the following command line:
acuthin [atc-user atc-password atc-splash-screen atc-trace] <atc-server>[:<atc-port>] [atc-runtime-options] <atc-alias> [<atc-cobol-args>]
As an example, assume the following command-line file components:
atc-server | myserver |
atc-port | 5633 |
atc-runtime-options | -lxe runtime.err |
atc-alias | myprog |
atc-cobol-args | 10 20 30 |
These command-line file contents are interpreted as the following command line: