APAR # |
PTF # |
APAR Description |
Notes |
PQ58602 |
UQ63672 |
OTMACI CLIENT FAILS INTERMITTENTLY
DURING SEND_RECEIVEX FOR /DIS COMMAND OUTPUT WITH SYSTEM_ERROR AND RSN=00000014 |
OTMA C/I CLIENT job fails
intermittently with with rc=0000000C rsn=00000014,00000003,xxxxxxxx,00000001
when it receives large output from IMS with multisegment message. The MPP that
processed it falls into WAIT state showing it is waiting
for response(ACK/NACK) from CLIENT. |
PQ59981 |
UQ79902 |
OTMA/CI XCFSTACK
STORAGE GROWS IN SUBPOOL 230 KEY 7 CAUSING OUT OF STORAGE
CONDITION AT HIGH VOLUMES |
SUBPOOL 230 KEY 7 grows as
volume of transactions increases in OTMA/CI environment.
XCFSTACK storage is being allocated even when there is
free XCFSTACK storage available. |
PQ58233 |
UQ63252 |
ABENDU0757 SC02B OR SC013 PROCESSING
AN ASYNC MESSAGE FOR OTMA. |
After IMS restart while output is available
on a HOLDQUE YQAB, IMS gets ABENDU0757 SC013 or SC02B in DFSQEQ00 or ABENDU0757 SC025
in DFSQGU00. |
PQ64243 |
UQ69205 |
IMS COMMUNICATION HANGS WHEN ISSUING A ROLB CALL
FROM AN OTMA C/I APPLICATION |
A message inserted to the IOPCB via an
APPC or OTMA transaction in synchronous conversation, following an application
ROLB call with a transaction defined as mode=MULTI, is incorrectly sent
asynchronously. |
PQ73927 |
UQ79301 |
ABENDU0757 SC0101 DFSQBFM0 PROCESSING
IMS CONNECT YQAB AFTER XRF TKO, EVEN AFTER PQ53178 |
ABENDU0757 SC0101 DFSQBFM0 processing
IMS Connect HOLDQUE YQAB After XRF TKO. Also, MSGDFS2610 during ERE
processing |
PQ80261 |
UQ82806 UQ82807 |
ABEND0C4 IN DFSYFD00 AFTER LABEL
@RC02798 ON CLC INSTRUCTION. REG11 HAS INVALID DATA. |
ABEND0C4 in DFSYFD00 due to bad address
in YDSTQTKN after PQ73927/UQ79301. |
PQ88003 |
UQ88712 |
OTMA/CI OTMA_SEND_ASYNC RECEIVES
RETURN CODE 20 FOLLOWING OTMA_SEND_ASYNC CALL GOES ON A WAIT |
OTMA Callable Interface client in
a wait after issuing an OTMA_SEND_ASYNC call. |
PQ88269 |
UQ94715 |
TRANSACTIONS FROM ORBIX VIA
OTMA HANG WITH WAIT-SYNCPOINT AFTER SENDING MULTI-SEGMENT OUTPUT MSG |
MPP is in a wait syncpoint state while sending a multi-segment
output message to an OTMA Callable Interface client. |
PK00406 |
UK03269 |
IMS OTMACI ERROR: OUT-OF-ORDER MSG
ISSUED BY DFSYOSRB WHEN PROCESSING A MULTISEGMENT MESSAGE |
Message IMS OTMACI Error: OUT-OF-ORDER
issued after applying PQ88269/UQ94715. |
APAR # |
PTF # |
APAR Description |
Notes |
PQ31893 |
UQ36236 |
FORWARD FIT FOR
APAR PQ29752 |
When input segment length >
256 bytes, OTMA C/I failed to copy the segment data to
the internal buffer. |
PQ34631 |
UQ42739 |
DFSYTIB0
MSGDFS1292E RECEIVED EVEN THOUGH CMDSECURE (/SECURE) OTMA
NONE SPECIFIED |
MSGDFS1292E received even
though /SECURE OTMA NONE was specified. |
PQ34643 |
UQ44378 |
AS/IMS RECEIVES SYSTEM ERROR
RC0C RSN02 . RC91 FROM OTMA CONDITION ANALYSIS. |
When OTMA C/I detected an
obsoleted IMS message, it issued a bad return code and
did not discard the message. |
PQ36642 |
UQ44386 |
ABEND202,RC=0, OR ABEND0C4 IN
IEAVEPST AFTER DFSYOFRE HAS DONE PC-POST FROM OFFSET
X'D80' |
Otma_free API tried to post an
ecb which was posted already. The ecb was filled with
garbage resulting in ABENDU0202. |
PQ36645 |
UQ45778 |
PROVIDE
ASYNCHRONOUS/UNSOLICITED MESSAGE SUPPORT FOR OTMA C/I. |
OTMA C/I needs to be expanded
to support unsolicited messages. New API calls are
introduced. |
PQ37322 |
UQ44377 |
OTMA DISPLAYS TBR
STATUS FOR TPIPE AFTER /ERE RESTART WHEN THE LAST TPIPE
MESSAGE SENT WAS MULTI-SEGMENT |
Before IMS abnormally
terminated, the last OTMA recoverable output message
segment which had sub-segments was processed incorrectly
as a non-recoverable output. |
PQ37862 |
UQ43992 |
OTMA C/I HUNG WHEN
RECEIVE BUFFER TOO SMALL FOR MULTI-SEGMENT OUTPUT |
Segment number in OTMA C/I
session control block was not updated correctly for the
async APIs causing user ECB to wait and not get posted. |
PQ42605 |
UQ54431 |
MPP IN
'WAIT-SYNCPOINT' AFTER U0031 ABEND |
After MPP abends with
abendu0031 and produced MSGDFS555I, region went into
'WAIT-SYNCPOINT' instead of getting abendu0119. |
PQ43258 |
UQ52484 |
OTMA/CI CLIENT RECEIVES DFS1283E
AND IMS MPR HANGS AT WAIT SYNCHPOINT PROCESS |
OTMA C/I client receives
MSGDFS1283E and IMS MPR hangs in Wait_Syncpoint. |
PQ48178 |
UQ57697 |
OTMACI CLIENT FAILS INTERMITTENTLY
DURING SEND_RECEIVEX FOR /DIS COMMAND OUTPUT WITH SYSTEM_ERROR AND RSN=00000014 |
OTMA C/I CLIENT job fails
intermittently with with rc=0000000C rsn=00000014,00000003,xxxxxxxx,00000001
when it receives large output from IMS with multisegment message. The MPP that
processed it falls into WAIT state showing it is waiting
for response(ACK/NACK) from CLIENT. |
PQ49398 |
UQ57016 |
IMS OTMA OUTPUT
HANGS AFTER NAK FROM C/I CLIENT |
OTMA C/I application hangs
after many otma_receive_async API calls are issued. |
PQ51470 |
UQ65071 |
OTMA C/I
SESSION_VECTOR = X'0', BUT A SESSION IS AVAILABLE, THUS
LEADING TO NO C/I SESSIONS AVAILABLE TO THE CLIENT |
OTMA C/I CLIENT slowly runs out
of C/I sessions. It gets RC=4, RSN=12 indicating
"session limit reached" on an allocation call. |
PQ51471 |
UQ65871 |
OTMA/CI XCFSTACK
STORAGE GROWS IN SUBPOOL 230 KEY 7 CAUSING OUT OF STORAGE
CONDITION AT HIGH VOLUMES |
SUBPOOL 230 KEY 7 grows as
volume of transactions increases in OTMA/CI environment.
XCFSTACK storage is being allocated even when there is
free XCFSTACK storage available. |
PQ53178 |
UQ61666 |
ABENDU0757 SC02B OR SC013 PROCESSING
AN ASYNC MESSAGE FOR OTMA. |
After IMS restart while output is available
on a HOLDQUE YQAB, IMS gets ABENDU0757 SC013 or SC02B in DFSQEQ00 or ABENDU0757 SC025
in DFSQGU00. |
PQ55157 |
UQ69350 |
IMS COMMUNICATION HANGS WHEN ISSUING A ROLB CALL
FROM AN OTMA C/I APPLICATION |
A message inserted to the IOPCB via an
APPC or OTMA transaction in synchronous conversation, following an application
ROLB call with a transaction defined as mode=MULTI, is incorrectly sent
asynchronously. |
PQ70666 |
UQ76626 |
ABENDU0757 SC0101 DFSQBFM0 PROCESSING
IMS CONNECT YQAB AFTER XRF TKO, EVEN AFTER PQ53178 |
ABENDU0757 SC0101 DFSQBFM0 processing
IMS Connect HOLDQUE YQAB After XRF TKO. Also, MSGDFS2610 during ERE
processing |
PQ80295 |
UQ82810 UQ82811 |
ABEND0C4 IN DFSYFD00 AFTER LABEL
@RC02798 ON CLC INSTRUCTION. REG11 HAS INVALID DATA. |
ABEND0C4 in DFSYFD00 due to bad address
in YDSTQTKN after PQ73927/UQ79301. |
PQ86634 |
UQ88711 |
OTMA/CI OTMA_SEND_ASYNC RECEIVES
RETURN CODE 20 FOLLOWING OTMA_SEND_ASYNC CALL GOES ON A WAIT |
OTMA Callable Interface client in
a wait after issuing an OTMA_SEND_ASYNC call. |
PQ88303 |
UQ94760 |
TRANSACTIONS FROM ORBIX VIA
OTMA HANG WITH WAIT-SYNCPOINT AFTER SENDING MULTI-SEGMENT OUTPUT MSG |
MPP is in a wait syncpoint state while sending a multi-segment
output message to an OTMA Callable Interface client. |
PK00457 |
UK03270 |
IMS OTMACI ERROR: OUT-OF-ORDER MSG
ISSUED BY DFSYOSRB WHEN PROCESSING A MULTISEGMENT MESSAGE |
Message IMS OTMACI Error: OUT-OF-ORDER
issued after applying PQ88303/UQ94760. |