APAR # |
PTF # |
APAR Description |
Notes |
PK07584 |
UK09100 |
SAME PROBLEM AS PK06242 IN IMS V9 - PE OF V9 PQ92841 - BACKFIT PK06242
TO V8 AND PE PQ99266(V8 05/11/10 PTF PECHANGE |
If an IMS transaction loops and RRS is in use check this APAR |
PQ54941 |
UQ60227 |
FORWARD FIT OF PQ50340 |
ABENDU0219 after entering cmd /DIS UOR.
The qbuffer passed exceeds max. length if it contains an XID, instead of the
normal EID |
PQ58194 |
UQ63218 |
FF PQ54006 |
ABENDU0766 RC07 in DFSIDSP0 for an ODBA
thread or ABENDU0768 RC06 in DFSIDSP0. |
PQ59431 |
UQ69204 |
ABEND0C4 IN DFSRRSI0 UNDER LABEL RRS1530 - REG 2 IS ZERO |
ABEND0C4 in module DFSRRSI0, under label
RRS1530, because register 2 is zero. R2 should be a PST address. |
PQ90900 |
UQ89956 |
AE PQ86550 FIX COMPLETION |
Module DFSRRSB0 not recompiled to
pick up changes made to DFSRRSIB macro after PQ86550. This could cause
module DFSRRSB0 to attempt to call the incorrect RRS service during IMS
Batch RRS execution. |
APAR # |
PTF # |
APAR Description |
Notes |
PQ32581 |
UQ40581 |
ABENDU0757 SUBCODE02B
DFSQEQ04 AT LABEL GFPD0410 |
During IMS
restart and during the processing of a /CHA UOR
ABORT command, incorrect backout sequence
performed for inflight UORs which are part of the
same syncpoint scope. Also, ABENDU0757-02B in
module DFSQEQ04, at label GFPD0410. |
PQ35783 |
UQ41543 |
IMS TERMINATES WITH
ABEND058 AFTER RRS ABEND |
ABEND058 or ABENDU0711
RC09 RCFFF in the IMS control region. |
PQ37325 |
UQ53832 |
ABENDU0762
RC02 FOLLOWED BY ABENDU0711 RC10 |
ABENDU0762 RC02
followed by AbendU0711 RC10. Also, during CHE
point processing an abend0C4 occurs in DFSRCP10
and restart of IMS abends with abend0C4 or
abendu3058. Also, an endless loop during DIS CCTL
ALL processing. Also, threads hung when
application fails to properly issue DPSB call in
a standalone environment. Also, duplicate
jobnames result in the pseudo abendu0136. |
PQ37368 |
UQ46116 |
ABEND0C4 IN DFSRDBP0 ON
RESTART |
After
PQ32581, abend0C4 occurs in module DFSRDBP0 on a
TM instruction, just after label LG47010, while
processing a TYPE47 log record during emergency
restart. |
PQ50340 |
UQ58254 |
ABENDU0219 AFTER ENTERING CMD /DIS UOR |
ABENDU0219 after entering cmd /DIS UOR.
The qbuffer passed exceeds max. length if it contains an XID, instead of the
normal EID |
PQ51164 |
UQ64692 |
ABEND0C4 IN DFSRRSI0 UNDER LABEL RRS1530 - REG 2 IS ZERO |
ABEND0C4 in module DFSRRSI0, under label
RRS1530, because register 2 is zero. R2 should be a PST address. |
PQ54006 |
UQ61331 |
DISPATCHER ABEND DUE TO ASCB/TCB MISMATCH |
ABENDU0766 RC07 in DFSIDSP0 for an ODBA
thread or ABENDU0768 RC06 in DFSIDSP0. |
PQ56473 |
UQ68927 |
ABENDU0711 FROM DFSRRSI0 DUE TO RRS ATTRWID FUNCTION |
ABENDU0711 issued as a result of DFSRRSI0 doing
an RRS ATRRWID call. RRS issued RC751, which means ATR_GEN_REQUIRED_XID and
DFSRRSI0 was not expecting this RC. |