The following table lists the properties of the mf.rts component and shows the event information that can be included in the trace for each property.
Event Level | Event ID | Event Description |
---|---|---|
INFO | 69 | Command Line. This event applies to managed COBOL only. |
INFO | 70 | Add Program Context. This event applies to managed COBOL only. |
INFO | 71 | Delete Program Context. This event applies to managed COBOL only. |
INFO | 74 | Version Info |
INFO | 128 | Start of run-time system initialization. This event applies to native COBOL only. |
INFO | 129 | End of run-time system initialization |
INFO | 130 | Start of run-time system de-initialization |
INFO | 131 | End of run-time system de-initialization |
INFO | 132 | Entered a COBOL container. This event applies to native COBOL only. |
INFO | 133 | Exited a COBOL container. This event applies to native COBOL only. |
INFO | 134 | Link level entered. This event applies to .NET managed code only. |
INFO | 135 | Link level exited. This event applies to .NET managed code only. |
INFO | 136 | Memory validating. This event applies to native COBOL only. |
INFO | 137 | Memory validated. This event applies to native COBOL only. |
INFO | 138 | Run-Unit Created. This event applies to managed COBOL only. |
INFO | 139 | Environment Exit. This event applies to managed COBOL only. |
INFO | 254 | STOP RUN |
ERROR | 246 | Shared memory error |
ERROR | 255 | Run-time system error |
Event Level | Event ID | Event Description |
---|---|---|
INFO | 56 | Entry to API. This event applies to native COBOL only.. |
INFO | 57 | Exit from API. |
Event Level | Event ID | Event Description |
---|---|---|
INFO | 61 | Run-time configuration operation (e.g. cobconfig file location and entries). |
Event Level | Event ID | Event Description |
---|---|---|
DEBUG | 40 | Server initialization (start/finish) |
DEBUG | 41 | Server de-initialization (start/finish) |
DEBUG | 42 | Server context initialization (start/finish) |
DEBUG | 43 | Server callback (start/finish) |
DEBUG | 49 | Request handler function (start/finish) |
INFO | 9 | Initializing environment for application running in the COBOL container (start/finish) |
INFO | 10 | Invoking application in the COBOL container (start/finish) |
INFO | 11 | Restoring initial state following the execution of an application in the COBOL container (start/finish) |
INFO | 25 | Request handler trace event |
INFO | 46 | Service lookup callback (start/finish) |
ERROR | 0 | Request handler "start/next request" error |
ERROR | 1 | Request handler "response" error |
ERROR | 2 | Request handler "end processing" error |
ERROR | 3 | Error loading the main program of the application identified by the request handler "start/next request" |
ERROR | 4 | Error loading the package containing the application identified by the request handler "start/next request" |
ERROR | 5 | Syncpoint failure |
ERROR | 12 | Application termination due to exit from Debugger |
Event Level | Event ID | Event Description |
---|---|---|
INFO and WARN | 60 | Environment variable operation |
Event Level | Event ID | Event Description |
---|---|---|
INFO | 26 | External data item created |
INFO | 27 | External data item destroyed. This event applies to native COBOL only. |
ERROR | 28 | External data item size mismatch |
Event Level | Event ID | Event Description |
---|---|---|
INFO | 52 | Entry to I/O function |
INFO | 53 | Exit from I/O function |
INFO | 54 | Specific I/O operation |
Event Level | Event ID | Event Description |
---|---|---|
INFO | 13 | Memory allocated |
INFO | 14 | Memory freed |
INFO | 15 | Memory re-allocated (resized) |
INFO | 16 | Re-allocated memory freed |
INFO | 17 | Memory remaining allocated at RTS termination |
INFO | 67 | Memory Strategy |
INFO | 68 | Memory Info |
ERROR | 248 | Memory allocation failure |
ERROR | 249 | Memory corruption detected. (See table below.) |
Memory type | Allocation method |
---|---|
51, 52 | CBL_ALLOC_MEM (with flags=0), or CBL_ALLOC_DYN_MEM (with flags=0) |
55, 56 | CBL_ALLOC_MEM (with flags=8), or CBL_ALLOC_THREAD_MEM (with flags=0) |
59, 60 | CBL_ALLOC_MEM (with flags=4), CBL_ALLOC_DYN_MEM (with flags=4), or CICS GETMAIN |
63, 64 | CBL_ALLOC_MEM (with flags=12) or CBL_ALLOC_THREAD_MEM (with flags=4) |
Stomp type | Reason | Description |
---|---|---|
0 | Run-In (Header) | Leading check bytes before header overwritten |
1 | Run-Out (User Data) | Trailing check bytes after user data overwritten |
2 | Bad Header | Corruption of memory header detected |
3 | Freed Overwrite | Previously freed data has been overwritten |
4 | Bad Header | User Unable to determine header start address |
5 | Failed OS Check | Validation of OS memory heap failed |
6 | Run-In (User Data) | Leading check bytes before user data overwritten |
7 | Bad Track Data | Leading check bytes in track data overwritten |
8 | Bad Link | Corruption of keyed data link |
Event Level | Event ID | Event Description |
---|---|---|
INFO | 55 | Entry Point Mapper function |
Event Level | Event ID | Event Description |
---|---|---|
INFO | 29 | Absolute memory registration |
INFO | 30 | External data registration |
INFO | 31 | Memory registration |
INFO | 32 | Working-storage memory registration |
INFO | 33 | External data de-registration |
INFO | 34 | Memory de-registration |
INFO | 35 | Working-storage memory de-registration |
INFO | 36 | Local-storage memory registration |
INFO | 37 | Local-storage memory de-registration |
ERROR | 250 | MFPM error. |
Event Level | Event ID | Event Description |
---|---|---|
INFO | 6 | Program entry |
INFO | 7 | Program exit |
INFO | 8 | Program chain. This event applies to native COBOL only. |
INFO | 18 | Program link. This event applies to native COBOL only. |
INFO | 140 | Section Entered |
INFO | 141 | Section Exited |
Event Level | Event ID | Event Description |
---|---|---|
DEBUG | 50 | Subsystem function. This event applies to native COBOL only. |
INFO | 19 | .int or .gnt program load |
INFO | 20 | Logical cancel |
INFO | 21 | Physical cancel. This event applies to native COBOL only. |
INFO | 22 | Logical canceled program made live again. This event applies to native COBOL only. |
INFO | 23 | DLL or shared object load. This event applies to native COBOL only. |
INFO | 24 | DLL or shared object unload. This event applies to native COBOL only. |
INFO | 38 | .lbr load. This event applies to native COBOL only. |
INFO | 39 | .lbr unload. This event applies to native COBOL only. |
ERROR | 251 | Program load error. This event applies to native COBOL only. |
Event Level | Event ID | Event Description |
---|---|---|
DEBUG | 58 | Entry to program searcher. |
DEBUG | 59 | Exit from program searcher. |
Event Level | Event ID | Event Description |
---|---|---|
INFO | 63 | Execute Process |
INFO | 64 | Wait On Process |
DEBUG | 73 | Run-Unit resource handling |
Event Level | Event ID | Event Description |
---|---|---|
INFO | 247 | Signal Signinfo |
ERROR | 252 | Apply previously ‘held’ signal |
ERROR | 253 | Signal caught |
Event Level | Event ID | Event Description |
---|---|---|
INFO | 6 | Program entry |
INFO | 7 | Program exit |
INFO | 8 | Program chain. This event applies to native COBOL only. |
INFO | 18 | Program link. This event applies to native COBOL only. |
INFO | 140 | Section entered |
INFO | 141 | Section exited |
Event Level | Event ID | Event Description |
---|---|---|
INFO | 56 | Entry to API (Threading and synchronization APIs) |
INFO | 57 | Exit from API (Threading and synchronization APIs) |
INFO | 142 | Thread status |
INFO | 143 | Thread killed |