The following table shows the LE general callable services that are supported by this COBOL system.
Routine
|
Description
|
Supported?
|
CEE3DMP
|
Generate dump
|
No *
|
CEE3PRM
|
Query parameter string
|
Yes
|
CEE3USR
|
Set/query user area fields
|
Yes
|
CEERAN0
|
Calculate uniform random numbers
|
Yes
|
CEETDLI
|
Invoke IMS
|
Yes
|
CEETEST
|
Invoke debug tool
|
No *
|
Note:
- Calls to unsupported routines marked by '*' are accepted but no action occurs. In the FEED_BACK condition (FC) code, the severity
is set to 4, the message number to 9999, and the facility-ID to MFX.
- Calls to unsupported routines marked by '**' are not accepted and if used in a COBOL program result in the fatal run-time
system error 173 ("Called program file not found in drive/directory").
- The FLGS data item in the FEED_BACK condition (FC) token is not set or used by this COBOL system.